10:13. Transmission range switch

Check

PERFORMANCE ORDER
1. Check that the starter works only at turn of a key in the ignition lock situation START and the selector lever in positions of P or N.
2. Check that lamps of a backing are lit only when moving the lever of the selector to a position R and a key in the ignition lock in situation START.
3. Check that position of the lever of the selector and indicator of the chosen position coincide.
4. Otherwise, check the transmission range switch.

Conductivity check

PERFORMANCE ORDER
1. Disconnect a wire from the negative plug of the rechargeable battery.
2. Disconnect the transmission range switch socket.
3. Check conductivity between contacts of the switch of range of the transmission.
4. If conductivity does not correspond to demanded, adjust or replace the transmission range switch.
5. Connect the transmission range switch socket.
6. Connect a wire to the negative plug of the rechargeable battery.

Adjustment

PERFORMANCE ORDER
1. Disconnect a wire from the negative plug of the rechargeable battery.
2. Lift the diagnostic socket from the sensor of the measuring instrument of a consumption of air (MAF) up.
3. Disconnect sockets of sensors of air temperature and the measuring instrument of a consumption of air.
4. Remove a zabornik of fresh air and the case of the air filter.
5. Turn out nuts. Disconnect a selector cable.
6. Move the selector lever to a position N.
7. Disconnect the transmission range switch socket.
8. Turn out bolts of fastening of the switch of range of the transmission.
9. Connect an ohmmeter between plugs 5 and 7.
10. Adjust position of the switch so that conductivity between contacts of the switch corresponded to demanded.
11. Tighten two bolts of fastening of the switch of range of the transmission.

Inhaling moment: 7,9-10,7 N of m

12. Check that conductivity of the switch of range of the transmission corresponds to demanded.
13. Connect the transmission range switch socket.
14. Connect a cable of the selector and fix by nuts.

Inhaling moment: 32–46 N • m

15. Establish the air filter and a zabornik of fresh air.
16. Connect sockets of sensors of air temperature and the measuring instrument of a consumption of air.
17. Install the diagnostic socket.
18. Connect a wire to the negative plug of the rechargeable battery.