1. Remove a ware box. |
2. Launch the engine and leave to work at idling rotation frequency. |
3. Turn on the switch of the conditioner and install for several minutes the fan switch on the highest frequency of rotation. |
4. Switch off the fan and stop the engine. |
5. Disconnect the conditioner thermoswitch socket. |
|
6. Additional wires connect the positive plug of the rechargeable battery to contact of 1 socket and the negative plug – to contact 4 sockets. Measure by the voltmeter tension on contacts 3 and 4 sockets. At a temperature about 4 °C tension has to be equal to 12 V, and at a temperature below 1 °C tension has to be equal to 0 Century. |
7. Otherwise, replace a conditioner thermal contact. |