1. In the presence, take off a belt of the drive of the pump of the amplifier of steering and the compressor of the conditioner. |
2. Weaken bolts of fastening of the generator and an adjusting bolt. |
3. Take off a generator drive belt. |
4. To establish a new belt of the drive of the generator. |
5. Tighten all bolts of fastening of the generator.
Inhaling moments Assembly bolt: 37–52 N • m Adjusting bolt: 19–26 N • m |
6. In the presence, establish a belt of the drive of the pump of the amplifier of steering and the compressor of the conditioner. |