18.8. Charging of standard batteries

PERFORMANCE ORDER
1. The battery is charged with current 3,5 - 4,0 And until density of electrolyte does not cease to change within not less than 4 hours.
2. The battery can also be charged with small current 1,5 A, having left for the night.
3. The accelerated charging of the rechargeable battery extremely is not recommended.
4. Electrolyte temperature at charging should not be above 37,8 °C.

Prevention

Before service or battery charging of a recharge, switch off everything consumers and stop the engine.

The negative wire needs to be disconnected first of all and to connect in the last turn.

If the accelerated battery charging is done by big current, install the battery in a container with water for an exception of its overheat.