5.16. Sensor of measurement of a consumption of air (TED)

Removal


Prevention

Do not throw and do not strike the sensor as it will lead to its damage.


PERFORMANCE ORDER
1. Disconnect the socket from the air consumption sensor.
2. Weaken collars of fastening of an inlet air branch pipe from two parties of the sensor of a consumption of air.
3. Disconnect an inlet air branch pipe from the air consumption sensor.
4. Turn out two bolts of fastening of the sensor of a consumption of air to an arm.
5. Remove the air consumption sensor.

Check

PERFORMANCE ORDER
Visually check the air consumption sensor on absence of damage. If necessary, replace it.

Installation

PERFORMANCE ORDER
1. Apply the air consumption sensor to an inlet air branch pipe and an arm.
2. Screw two bolts of fastening of the sensor to an arm.

Inhaling moment: 7,8–10,8 N • m

3. Connect an inlet air branch pipe to the sensor.
4. Tighten collars from two parties of the sensor.
5. Connect the socket to the air consumption sensor.
6. Launch the engine and warm up it up to the normal working temperature. Leave the engine to work at idling rotation frequency.
7. Connect the voltmeter between contact 4 (RED/WHT a wire) and weight.
8. Make sure that tension changes within 0,8–1,2 Century.
9. Switch off the engine and be convinced that tension is in limits of 3,5-4,0 Century.