5.4. The filtering element of the air filter

Removal

PERFORMANCE ORDER
1. Weaken a collar of fastening of a branch pipe of an air inlet on the air consumption measuring instrument sensor.
2. Disconnect an air inlet branch pipe from the air consumption measuring instrument sensor.
3. Turn out six bolts of fastening of a cover of the air filter and remove it.
4. Remove the filtering element of the air filter from the case.

Prevention

Do not use compressed air for cleaning of the filtering element of the air filter.


5. Check the filtering element of the air filter for lack of pollution, damages and hit of oil on it.
6. If necessary, replace the filtering element of the air filter.

Installation

PERFORMANCE ORDER
1. Install the filtering element of the air filter in the case of the air filter.
2. Establish a cover of the air filter and fix by six bolts.
3. Connect an air inlet branch pipe to the sensor of the measuring instrument of a consumption of air and fix it by a collar.